Configuration
CPU 317T: Technology Functions
4-36 A5E00251798-03
4.5.4 High resolution
Encoder pulses can be evaluated in the drive at a higher resolution, depending on
the encoder registration and type. The configuration of signal evaluation in the
drive must be interconnected with the "Multiplication factor of the cyclic actual
value" parameter in the axis configuration in S7T Config.
Example
An incremental encoder is connected to SIMODRIVE 611U and returns 2048 p/rev
(encoder scaling). By default, the drive multiplies this number of pulses by a
coefficient of 2048 (2exp11.) This factor must be entered at the "Multiplication
factor of the cyclic actual value" parameter.
Default
The default "Multiplication factor of cyclic actual value" is set to "0." In this case, the
system automatically uses the multiplication factor of 2048 (2exp11.)