Connect Tech CPU Manual de servicio Pagina 160

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 650
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 159
Configuration
CPU 317T: Technology Functions
4-84 A5E00251798-03
The sense of the synchronization movement is set in the "Synchronization
direction" drop-down list. This setting is only available for modulo axes.
Setting Meaning
User default / default The default value can be set by means of the following configuration
data in the expert list:
Setting for gearing:
userdefault.gearingsettings.synchronizingdirection
(parameter 4291 for MC_ReadSysParamter, MC_WriteParameter)
Settings for camming:
userdefault.cammingsettings.synchronizingdirection
(parameter 4270 for MC_ReadSysParamter, MC_WriteParameter)
Compatibility mode Same reaction as in Version 3.0.x of the firmware of the integrated
technology.
Shortest distance without
direction preset
The following axis is synchronized within the shortest possible
distance.
Negative direction of the
synchronization motion
The direction of the synchronization motion is always negative.
Positive direction of the
synchronization motion
The direction of the synchronization motion is always positive
Maintain the direction of the
following axis
Synchronization is always determined by the direction of the following
axis motion.