Technology functions
CPU 317T: Technology Functions
A5E00251798-03
6-115
ErrorID
Error message Description / to correct or avoid error
8084 Invalid technology DB A technology object does not exist in the PLC for the
technology DB specified at input parameter Axis.
Download the current technology to the PLC, or
change the DB number at input parameter Axis.
The user has written invalid data to the technology
DB specified at input parameter Axis.
In "Technology Objects Management", delete and
then recreate the technology DB.