Technology DBs
CPU 317T: Technology Functions
7-22 A5E00251798-03
Variable MeasureStart/MeasureEnd
The MeasureStart variable indicates the lo limit, the MeasureEnd variable the hi
limit of the measuring hysteresis. Only the measured values within this hysteresis
are logged. When the MeasureStart and MeasureEnd values are equal, the
hysteresis has no effect.
The MeasureStart/MeasureEnd variables shown at the DB correspond with the
values of the input parameters of the relevant FB 433 "MC_MeasuringInput."